Retrofit · Switchgear modernisation

New life for existing switchgear

Modernise 0.4–35 kV switchgear without replacing the panels: from fitting a new circuit breaker to a complete upgrade of protection, metering and control.

Where their suitability is confirmed, panel enclosures, busbars and cable connections remain in place while worn equipment is replaced. A basic retrofit replaces an end-of-life breaker with a new vacuum circuit breaker. A Smart retrofit upgrades the entire bay: circuit breaker, measurements, protection and automation, energy metering and dispatch communications — in one kit from one manufacturer.

Before work starts, Tavrida Electric engineers inspect the facility, identify what can be retained and select an installation method: a mounting kit or a complete withdrawable unit.

Select a solution
Switchgear modernisation solutions: Smart04, a 6(10) kV retrofit kit and 35 kV outdoor switchgear
Retrofit · 0.4–35 kV
0.4–35 kVModernising existing switchgear
4 retrofit categories0.4 kV switchgear, 6(10) kV metal-clad and metal-enclosed switchgear, and 35 kV indoor and outdoor switchgear
Basic and Smart retrofitThe extent of modernisation tailored to your facility

Modernisation requirements

When is it time to modernise switchgear?

If the panel enclosures, busbars and insulation are serviceable but the circuit breakers, transformers and protection are worn, the components inside the panels can be upgraded. Retrofit feasibility is confirmed by inspection. Four signs that a retrofit is due:

01

Circuit breakers have reached the end of their service life

Oil and air circuit breakers require regular repairs, while finding parts for discontinued series can take months. Under the specified operating conditions, a Tavrida Electric vacuum circuit breaker requires no maintenance or repairs throughout its service life and can be installed in the existing panel after compatibility checks.

02

The relay protection system is outdated

Many facilities still use electromechanical relays. Their operating characteristics drift over time, and existing schemes may not selectively clear earth faults in 6(10) kV networks, requiring successive feeder disconnections to locate the fault. Digital protection integrated into the circuit breaker control module addresses these issues and is configured for the facility’s specific arrangement.

03

No network operating data

Without remote measurements and an event log, outages are reported by consumers and their causes require a substation visit. A Smart retrofit can include an individual router for each panel or a complete remote control cabinet to send currents, voltages, breaker positions and event logs to the dispatch centre.

04

Extended shutdowns are not an option

Ready-made mounting kits help reduce on-site work. Installation and commissioning times are determined after inspection, taking account of switchgear condition and available outage windows. Where the arrangement permits, panels are modernised one at a time without shutting down the entire bus section.

Retrofit · Solution 01 · 0.4 kV modernisation

Retrofit of АВМ and Электрон breakers without replacing the entire switchgear

Smart04 is a ready-made retrofit solution for АВМ and Электрон series breakers in existing 0.4 kV switchgear. It combines a vacuum switching module, digital protection, measurements, control and data transmission.

The solution upgrades the circuit breaker and its functions without replacing the entire cabinet, provided the enclosure remains serviceable. Inspection determines whether the withdrawable base and current-carrying connections can be retained.

The kit includes a vacuum circuit breaker, current and voltage sensors, a control module and panel, communications equipment, a mounting kit and interlocks. The version is selected according to the installed breaker type, cabinet design and feeder parameters.

By default, auxiliary power is supplied directly from the current-carrying parts through the voltage measurement circuits.

Smart04 provides configurable digital overcurrent protection, network parameter monitoring, event recording and data transmission to the dispatch system. Depending on the version, the solution may include automatic transfer, normal supply restoration, arc protection, operational energy metering and remote control.

Retrofit kits have been developed to replace AVM (AVM04–AVM20) and Elektron (E16–E40) circuit breakers.

Smart04 vacuum circuit breaker, 1600 A — control-side view
Smart04, 1600 A · control-side view
Smart04 vacuum circuit breaker, 1600 A — contact-side view
Smart04, 1600 A · contact-side view
Smart04, 2000 A — contact-side view
Smart04, 2000 A · contact-side view
Smart04 for replacing АВМ20 — control-side view
Smart04, 2000 A · control-side view
1 / 4

Key technical specifications

Switchgear voltage class
Value0.4 kV
Switching module rated current
ValueUp to 3150 A
Rated voltage
Value400/690 V
Breaking capacity
ValueUp to 50 kA
Electrical endurance at rated current
Value30000 C–O cycles
Operating temperature range
Value−45…+55 °C
Control module auxiliary power supply
Value85–265 V AC/DC
Design
ValueFixed or withdrawable

The permissible current of the upgraded feeder is determined by the ratings of the retained busbars, contacts and other switchgear components.

Applications

  • Replacement of incomer, bus-section and outgoing feeder breakers of the AVM and Elektron series
  • Facilities where serviceable cabinet structures need to be retained
  • Switchgear requiring modern protection, automation and monitoring functions
  • Plants where prolonged process shutdowns are unacceptable
  • Plants where an existing breaker failure could cause critical equipment downtime or prolonged power restoration

Key benefits

  • Targeted feeder modernisation without replacing the serviceable switchgear cabinet
  • Configurable digital protection
  • Network parameters, breaker status and event logs available locally and through the dispatch system
  • Automatic transfer and arc protection in applicable versions
  • Maintenance-free circuit breaker
  • 7-year solution warranty

Retrofit · Solution 02 · Upgrading 6(10) kV metal-clad and metal-enclosed switchgear

From breaker replacement to a complete panel upgrade

Mounting kits and complete withdrawable units for modernising 6(10) kV metal-enclosed switchgear and fixed, single-front-access KSO panels — from breaker replacement to a complete bay upgrade.

A basic retrofit replaces the breaker with a ВВ/TEL vacuum circuit breaker while retaining existing protection. A Smart retrofit goes further: combined current and voltage sensors and a control module replace the current and voltage transformers, relays and meter. The module provides protection and automation, revenue energy metering and breaker control. Equipment, operating logic, documentation and technical support come from one manufacturer under a single point of responsibility.

A standard mounting kit is supplied for metal-enclosed switchgear panels. For metal-clad switchgear panels, the options are a mounting kit that fits the existing withdrawable base or a ready-to-install withdrawable unit. The choice depends on the panel design and the condition of its contacts, interlocks and secondary circuits. The range of mounting kits covers a wide variety of panels made in Russia and abroad.

Retrofit kit for 6(10) kV metal-enclosed switchgear
Retrofit kit for metal-enclosed switchgear
Smart retrofit kit for 6(10) kV metal-enclosed switchgear
Smart retrofit kit for metal-enclosed switchgear
Withdrawable unit for retrofit of 6(10) kV metal-clad switchgear
Retrofit kit for metal-clad switchgear
Smart retrofit kit for metal-clad switchgear, designed to fit the existing circuit breaker truck
Smart retrofit kit for metal-clad switchgear
Ready-to-install withdrawable unit for Smart retrofit of 6(10) kV metal-clad switchgear
Withdrawable unit for Smart retrofit of metal-clad switchgear
1 / 5

Basic retrofit

New circuit breaker

The ВВ/TEL vacuum circuit breaker is installed using a mounting kit or as part of a complete withdrawable unit. The panel’s original interlocks are restored.

Smart retrofit

Complete bay upgrade

The circuit breaker, combined sensors and control module operate as one system. The module provides protection and automation, including selective earth-fault protection for any neutral earthing arrangement, revenue energy metering and SCADA data transmission. Arc protection is integrated, and signals between panels are exchanged over the ArcNet2 bus.

Key technical specifications

ParameterBasic retrofitSmart retrofit
Rated system voltage
Basic retrofit6(10) kV
Smart retrofit6(10) kV
Rated current
Basic retrofitUp to 3150 A
Smart retrofitUp to 3150 A
Rated short-circuit breaking current
Basic retrofitUp to 50 kA
Smart retrofitUp to 50 kA
Installation method
Both retrofit optionsMounting kit or complete withdrawable unit

Maximum current ratings depend on the kit version and are not available in every combination. Permissible upgraded-panel ratings are checked against the components retained.

Retrofit applications

  • Metal-enclosed switchgear panels with fixed circuit breakers
  • Metal-clad switchgear panels with withdrawable units
  • Metal-clad switchgear requiring a new ready-to-install withdrawable unit
  • Imported panels following compatibility checks

Key benefits

  • Complete, ready-to-install Smart retrofit kit — from circuit breaker to SCADA integration
  • Equipment, operating logic, documentation and support under one responsibility
  • Selective single-phase earth-fault protection for any neutral earthing arrangement
  • Integrated arc protection and inter-panel data exchange over ArcNet2

6(10) kV configurator

Which solution fits your panel?

Enter the panel type, installed breaker and feeder parameters. The configurator will help identify a retrofit option and prepare a request to Tavrida Electric.

Open the retrofit configurator

Retrofit · Solution 03 · 35 kV indoor switchgear modernisation

Vacuum circuit breaker with integrated sensors for 35 kV indoor switchgear

Replacing circuit breakers and upgrading measurements, protection and control in existing 35 kV indoor switchgear panels.

The panel enclosure is retained. Inspection checks insulation, busbars, current-carrying parts, interlocks and secondary circuits to determine the scope of supply.

The Smart retrofit is based on the ISM35 switching module with current and voltage sensors integrated into its poles. The bay controller combines breaker control, measurements, protection and automation, energy metering and data transmission to the substation control system.

Withdrawable unit for Smart retrofit of 35 kV metal-clad switchgear
Withdrawable unit for Smart retrofit of 35 kV metal-clad switchgear
Smart retrofit kit for 35 kV metal-clad switchgear
Smart retrofit kit for 35 kV metal-clad switchgear
1 / 2

Key technical specifications

Rated system voltage
Value35 kV
Rated current
ValueUp to 1250 A
Rated short-circuit breaking current
ValueUp to 25 kA
Short-time withstand current duration
Value3 s
Current and voltage measurement
ValueSensors integrated into the poles

Specifications and components of each version are confirmed during selection.

Retrofit applications

  • 35 kV metal-clad switchgear with a withdrawable unit
  • 35 kV metal-clad switchgear requiring a new, ready-to-install withdrawable unit
  • Imported panels following compatibility checks

Key benefits

  • Existing indoor switchgear panels remain in place
  • Circuit breaker, measurements, protection and metering in one kit
  • Current and voltage sensors integrated into the breaker poles
  • Data transmission to the substation control system

Retrofit · Solution 04 · 35 kV outdoor switchgear modernisation

Outdoor vacuum circuit breaker and digital protection for 35 kV switchgear

Basic and Smart retrofit of 35 kV outdoor switchgear: replacement of the switching device and control module or a complete bay functionality upgrade.

Smart retrofit is the primary option. It replaces the circuit breaker and upgrades measurement, relay protection and automation in a single project. If the substation’s existing relay protection is up to date and meets the site’s requirements, a basic retrofit is sufficient. In this case, a new circuit breaker is installed with a control module that connects to the existing relay protection and automation system once compatibility has been confirmed.

The Smart retrofit is based on the outdoor OSM35_Smart_7 switching module, a control cabinet, connection unit and primary-equipment mounting kit. The project defines adaptation to existing outdoor structures and any additional components.

Kit for 35 kV outdoor switchgear Smart retrofit
Kit for 35 kV outdoor switchgear Smart retrofit

Basic retrofit

New circuit breaker

A new vacuum circuit breaker and control module connect to existing secondary circuits. Suitable where existing protection and automation are serviceable, meet facility requirements and are compatible with the new equipment.

Smart retrofit

Complete bay upgrade

Measurements, protection and automation, energy metering and data transmission are added to the breaker. The project determines the scope.

Key technical specifications

Rated system voltage
Value35 kV
Rated current
ValueUp to 1250 A
Rated short-circuit breaking current
Value25 kA
Climatic version
ValueUHL1 (outdoor operation in temperate and cold climates, per GOST 15150-69)
Operating temperature range
Value−60…+55 °C
Installation
ValueOutdoor

Specifications and components of each version are confirmed during selection.

Applications

  • 35 kV outdoor switchgear with oil and other outdated circuit breakers
  • Substations with modern protection requiring a new switching device
  • Substations requiring a complete protection and control upgrade

Key benefits

  • Two options: a new circuit breaker and control module or a complete bay upgrade
  • Outdoor UHL1 version for temperatures down to −60 °C
  • Primary-equipment mounting kit included in the supply
  • Measurements, protection and metering included in the Smart retrofit

Frequently asked questions

What to check before modernisation

When is a retrofit more economical than new switchgear?

When inspection confirms that panel enclosures, busbars, contacts and insulation are fit for continued service. Retaining panels and cable connections reduces work and cost. The final decision follows a comparison of cost, timescale and required functionality.

What is the difference between basic and Smart retrofit?

A basic retrofit replaces the breaker: installation, control circuit connection and restoration of interlocks. A Smart retrofit upgrades the whole bay: current and voltage transformers, relays and meter are replaced with current and voltage sensors and a control module providing protection, metering and SCADA data transmission.

Can the existing relay protection be retained?

Yes, if it is serviceable, meets facility requirements and is compatible with the new breaker. Otherwise, it is upgraded within the project.

Does the entire withdrawable unit need replacing?

For metal-clad switchgear, a new circuit breaker can be fitted to the existing withdrawable trolley if it is suitable for reuse. Alternatively, a new, ready-to-install withdrawable unit can be supplied. The choice depends on the condition of the trolley, disconnecting contacts and interlocks, as well as on compatibility with the switchgear panel.

Can modernisation be carried out in stages?

Yes. Panels can be modernised individually or in groups where the power supply arrangement and outage schedule permit. If protection, metering and SCADA connectivity are required, they can be included in the Smart retrofit from the outset and integrated into the overall modernisation plan.

How long does a retrofit take?

The timescale depends on equipment condition, modifications, secondary circuits, testing and available outage windows. We confirm the exact duration after inspection. Ready-made mounting kits and Smart retrofit help reduce installation and commissioning work.

Will replacing the breaker increase the panel’s permissible current?

No. A higher-rated breaker does not increase the permissible current of the whole panel: the retained busbars, contacts and other components must be checked separately.

What information is needed for preliminary selection?

Switchgear type and series, installed breaker data, rated voltage and current, short-circuit current at the installation point, feeder diagram, auxiliary supply type, and protection and control requirements. Attach photographs of the panel and equipment nameplates.

Technical consultation

We will select a solution for your switchgear

Send a feeder diagram, installed breaker data and photographs of the panel. Tavrida Electric engineers will review the information, propose a retrofit option and advise what to check during inspection.

Get technical advice
  • Scope tailored to your taskСircuit breaker replacement only or a complete Smart retrofit.
  • Compatibility checksSwitchgear design, network parameters, existing protection and remote control.
  • Agreed scope of workWhat stays, what changes and in what sequence.