Voltage dips stop production
A brief power disturbance can stop pumps, motors, conveyors, variable-frequency drives, contactors and control systems. For critical loads, standby transfer time is measured in tens of milliseconds.
When standard circuit breaker specifications are not enough
Solutions based on special vacuum circuit breaker versions for fast automatic bus transfer, controlled synchronous switching and high-duty loads. Selected according to network conditions, load characteristics and operating duty.
Preliminary selection based on facility parameters and load operating duty.
A brief power disturbance can stop pumps, motors, conveyors, variable-frequency drives, contactors and control systems. For critical loads, standby transfer time is measured in tens of milliseconds.
Energising inductive or capacitive loads at a random instant may cause inrush currents and switching overvoltages. This places additional stress on insulation, transformers, cables and other equipment.
Industrial processes such as arc furnace operation may require hundreds of switching operations per day. A standard breaker is not designed for this duty without regular maintenance and repairs.
Fast automatic bus transfer for 0.4–10 kV networks. The system uses VCB15_FT high-speed vacuum circuit breakers. It automatically transfers the load to the standby source when the main supply parameters are outside limits.
The terminal continuously monitors the network and decides when to transfer. VCB15_FT high-speed circuit breakers complete the entire load transfer cycle in up to 40 ms.
A synchronous switching device for 6–35 kV networks. Used for inductive and capacitive loads where inrush currents and switching overvoltages need to be reduced.
The controller continuously measures network voltage, phase and frequency, then commands each breaker pole at the optimum instant. Synchronous switching accuracy is ±1–2 ms.
*Results depend on the network arrangement, load type and specific facility parameters.
VCB15_AF and VCB35_AF circuit breakers are designed for processes with extremely high switching rates. A key application is switching furnace transformers at steelmaking plants.
Depending on the version, equipment is rated for 40000, 80000 or up to 150000 C–O operations without maintenance. Fixed and withdrawable versions are available for integration into various panel types.
Answers about fast bus transfer, synchronous switching and circuit breakers for intensive duty.
Fast automatic bus transfer is used where even a brief power loss can stop critical loads: pumps, motors, conveyors, variable-frequency drives, process control systems or a production line. It automatically transfers supply to a standby source in up to 40 ms.
Conventional automatic transfer follows a standard algorithm, but its speed may not keep sensitive or critical loads running. Fast bus transfer uses VCB15_FT high-speed vacuum circuit breakers and completes the transfer cycle in up to 40 ms, helping reduce process shutdown risks.
Fast bus transfer solutions are used in 0.4–10 kV networks with rated currents of 630–4000 A. The version is selected according to the power supply arrangement, bus-section parameters, load operating modes and short-circuit currents.
Controlled switching is used for capacitive and inductive loads in 6–35 kV networks: capacitor banks, transformers, reactors and cables. It is relevant where inrush currents and switching overvoltages affect equipment life or process stability.
The controller continuously measures network voltage, phase and frequency, then issues a closing command to each breaker pole at the optimum instant. Synchronous switching accuracy of ±1–2 ms reduces closing inrush currents and switching overvoltages.
No. Controlled switching reduces the likelihood and severity of adverse switching transients, but results depend on network configuration, load and cable parameters, protection and operating conditions. Initial data and switching scenarios must be analysed before selection.
VCB15_AF and VCB35_AF circuit breakers are intended for facilities performing tens or hundreds of operations per day. A typical example is furnace transformer switching in steelmaking. They also suit other energy-intensive processes with demanding switching endurance requirements.
Depending on version and application conditions, breakers are rated for 40000, 80000 or up to 150000 maintenance-free C–O cycles. This reduces scheduled maintenance and the risk of unplanned shutdowns caused by switching device wear.
Yes. Fast bus transfer, controlled switching and high-duty breakers can be used in new switchgear and retrofit projects. Over 250 integration kits are available for fast bus transfer; suitability for an existing panel is established after checking its design, network parameters and operating conditions.
Preliminary selection requires a single-line power supply diagram, rated voltage and current, short-circuit currents, load composition and criticality, switching scenarios, power restoration time requirements, and details of existing switchgear and panels.
Could not find an answer? Send a single-line diagram and the main network parameters, and our specialists will prepare a technical solution.
Get adviceWe will analyse the power supply arrangement and propose fast bus transfer, controlled switching or a high-duty circuit breaker, taking account of network parameters, critical loads and the project’s economic case.